  1. Changes in the 2024 International Building Code (IBC)

    Oct 16, 2009 · The 2024 IBC® contains many important changes such as: Duties and powers of the building official: an overall reformat of Section 104 regulating duties of the building official, the …

  2. Egress Capacity Calculator - 2024 IBC

    Interactive calculator for means of egress using 2024 IBC Section 1005, Table 1020.3, and Section 1010.1.1 for doors.

  3. Occupancy Classification for Townhouse: R-2 or R-3?

    Oct 17, 2009 · R-2: "Residential occupancies containing more than two dwelling units" If each townhouse is a seperate structure, than it only contains one dwelling unit. That makes it R-3, yes?

  4. Group E Occupancies Explained - IBC 305 (2024) - The Building Code …

    Oct 16, 2009 · Do you agree with the following interpretation and summary of this important section? Definition and Scope of Group E Occupancies: Group E occupancy primarily involves buildings or …

  5. 1, single user, unisex toilet room in coffee shop, per 2021 IBC

    Feb 24, 2025 · The IBC Commentary language for exception #5 confirms this. There is also the exception under the calculations portion , 2902.1.1, reading "Distribution of the sexes is not required …

  6. 1006.2.1 Egress based on occupant load and common path of egress …

    Dec 23, 2020 · 2021 IBC Section 1006.2.1 requires that two exit or exit access doorways shall be provided to any space if the design occupant load or the common path of egress travel exceeds the …

  7. Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and ...

    Oct 16, 2009 · Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted. It outlines the scope, purpose, and administrative …

  8. Shaft vs. Chase - The Building Code Forum

    Jun 8, 2017 · The term "chase" isn't defined in the IBC and the term "chases" is only mentioned 3 times (408.5.2, 2104.1.4, and 3412.6.3 (2012 IBC)). I find UL listings for both chases and shafts and I hear …

  9. College classroom: B or A-3 occupancy? - The Building Code Forum

    Dec 27, 2022 · Is the ‘Classroom area’ function in IBC Table 1004.5 considered an assembly function for the purpose of determining if a college classroom needs to be classified as an A-3 occupancy group? …

  10. Water Fountain Substitution - The Building Code Forum

    Dec 23, 2014 · 2009 IBC 2012 IBC Chapter 11 2009 IPC 2009 ICC A117.1 A117.1 requires one low and one high water fountain. IPC Section 410 allows 50% of drinking fountains to be replaced by water …